The use of slurry pumps
Check before starting:
Check whether the pump body, pipeline, lubricant and power source are normal.
Fill water and exhaust (such as non-self-priming pumps).
Starting steps:
Turn on the cooling water first, slowly open the outlet valve after starting the motor.
Adjust the valve to ensure normal flow and pressure.
Attention during operation:
Monitor the vibration, noise, pressure, flow rate and bearing temperature of the pump (≤70°C).
Avoid large particles or excessively thick slurry from entering the pump body.
Shutdown operation:
Close the outlet valve first, then stop the motor, clean the pump body and empty the slurry.
Stop the cooling water and disconnect the power.
Regular maintenance:
Clean the pump body, check the impeller, seals, bearings and other wear parts, and replace the lubricating oil regularly.
Note: Avoid dry spinning and overload operation, make sure the slurry is within the pump design range.
If you don't know how to choose the right water well Drilling Rig, click the link below to contact our professional team directly.
Contact: Mr Chen
Phone: +86 18574606855
Tel: +86 746 8323309
Email: pearldrill02@guangzhouintl.com